--- title: "Clarity Ratios" slug: "clarity-ratios" updated: 2026-09-09T20:47:44Z published: 2026-09-09T20:47:44Z canonical: "doc360.rationalacoustics.com/clarity-ratios" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Clarity Ratios ## Early-to-Late Energy Ratios Early-to-late energy ratios are another way of objectively characterizing the reverberant characteristics of a room. They are arguably a better measure than Reverberation Time for any venue where a sound system is an organic part of the acoustical equation. They are simple to calculate automatically and are not subject to the kinds of complications that can make measurement of reverberation times somewhat subjective, but they are a more recent innovation and may be less widely understood than RT60. ## Clarity Ratios (C35, C50, C80…) Clarity indexes are early-to-late energy ratios that compare the integral of the energy arriving within the first *n* milliseconds of the arrival of direct sound (inclusive) to the energy in the remainder of the reverberant decay period. The two most commonly used are C50 and C80, which use 50 or 80 milliseconds respectively as their split times. The result of the comparison is expressed as a Decibel ratio. Shorter split times such as 35 or 50 ms, however, are regarded as better predictors of speech intelligibility. C80, on the other hand, is more useful for music. In terms of what kinds of numbers to look for, Gerald Marshall provided the below table in a 1996 *Journal of the AES* article titled *An Analysis Procedure for Room Acoustics and Sound Amplification Systems Based on the Early-to-Late Sound Energy Ratio*. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-09-09 at 16-45-15.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A12Z&se=2026-11-18T18%3A42%3A12Z&sr=b&sp=r&sig=0CAWAa503bEwPySX6WnrK4DS1yy6KR19%2FEb8dVQ0T1Q%3D) *A recreation of Marshall’s scale for interpreting C50 and C80 measurement results for speech and music.* For the speech intelligibility scale, Marshall used a weighted average of the 500 Hz to 4 kHz octave bands, with the following weights assigned to each band: 15% for 500 Hz, 25% for 1 kHz, 35% for 2 kHz and 25% for 4 kHz. Others have used the weighting tables for Articulation Index, STI and scales of their own devising with similar results. For music, he used a simple average of the 500 Hz, 1 kHz and 2 kHz octave bands. We know of no applicable standards for this metric and it has been suggested extending the frequency ranges that Marshall used an octave higher for speech and two octaves higher for music might be useful, but hopefully this example provides a useful starting point for evaluation. In acoustics, the amount of time required for audio energy introduced into a system (typically a room) to diminish, or decay by 60 decibels following the cessation of a stimulus signal used to excite the system — e.g., a balloon pop, gun shot or terminated pink noise. It is normally stated band-by-band for individual octave bands. By convention, decay times are normalized to the time required for 60 dB of decay at an observed rate of decay, regardless of the amplitude range actually measured. 60 dB decay time is often referred to as “RT60” or “T60", which is sometimes a source of confusion. And just to confuse things a little more ISO 3382 specifies that it should be called T20 or T30, where the “20" and “30” refer to the decay range actually measured. The main thing to remember is that all of the above refer to 60 dB decay time within a stated frequency range. When a single-number reverberation time is given, according to the ISO standard it should be the average of the reverberation The decibel, often abbreviated as dB, is a logarithmic ratio between two values. In electronics and acoustics, decibels most commonly refer to the ratio between a given amplitude value and the number 1, where some reference value such as the maximum output of an A/D converter (dB Full Scale or dBFS) or the threshold of audibility for human hearing (for dB SPL) is scaled to equal 1. The decibel value for an amplitude is then calculated as: dB = 20·Log10(A) = 10·Log10(A 2 ), where A is linear amplitude. In this case, amplitude values greater than one yield positive decibel values and numbers smaller than one become negative dB values. This is why dB FS values are most often negative and dB values in sound level measurements are nearly always positive.