--- title: "Audient EVO® Control Integration" slug: "audient-evo-control-integration" status: "new" updated: 2026-10-28T18:55:59Z published: 2026-10-28T18:55:59Z canonical: "doc360.rationalacoustics.com/audient-evo-control-integration" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Audient EVO® Control Integration Since v9.1, Smaart has integrated gain and phantom power control for the Audient Evo® series interfaces, as well as a gain tracking feature. > [!NOTE] > **Smaart supports Audient’s EVO 4, 8, and 16 devices. (Smaart does not support the Audient EVO SP8 mic preamp.)** ## Driver & Control App For both the Roland Octa-Capture and Audient EVO interfaces, device-appropriate control software needs to be installed and running before connecting your device to your computer for the first time. (On Windows, please install the driver as an Administrator). **Your device’s control program must be launched before Smaart for the preamp, phantom power, and gain tracking controls to display**. If you close Smaart, you must also close and the reopen the app to re-establish control. - [EVO control software and drivers are available from Audient’s website here.](https://audient.com/) - [Octa-Capture control software and drivers are available from Roland’s website here.](https://www.roland.com/global/support/by_product/octa-capture/updates_drivers/) > [!WARNING] > **The EVO/Octa-Capture control app must be launched before opening Smaart for the input gain, phantom power, and gain tracking controls to display**. ## Gain and Phantom Power Control When using an interface with Smaart integration, you can toggle phantom power and control gain for each input from within the *Input Meters* window. This window can be accessed either by navigating to *View > Input Meters > Input Meters* or by using the [Shift] + [E] hot key. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(334).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A06Z&se=2026-11-18T18%3A30%3A06Z&sr=b&sp=r&sig=a%2BQfvCJRUcZCMhMKiQSL5%2BrcarKv9qw4J5F%2BqOdNfkY%3D) *Input Meters Window featuring control integration.* These controls are also available in the *Amplitude* *Calibration* dialog. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(343).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A06Z&se=2026-11-18T18%3A30%3A06Z&sr=b&sp=r&sig=%2BYw8OB8iVsDMBM%2FNGGmtDK4NfcD9ZsIgoPK1et1Dngs%3D) *Amplitude Calibration dialog featuring control integration.* > [!NOTE] > **EVO devices have 58 dB of gain, but Smaart is designed to allow for 50x 1dB gain steps. As such, 0 dB in Smaart = 0 dB on the EVO. However, the EVO control app will show more available** Attenuation**. If you attenuate the EVO below 0dB (as read in Smaart), that level will not be reflected in Smaart’s Input Meters.** ## Gain Tracking Gain tracking, once enabled, allows Smaart’s calibration offset to adapt to changes in the input level/preamp gain when controlled from within Smaart’s “Input Meters” window (as discussed above). The accuracy of these adjustments may vary from device to device, in a typical range within a maximum error of about +/- 1 dB from 0-50 when calibrated at a gain setting of 25 dB. Once an input is calibrated for SPL measurement, Gain Tracking can be toggled on/off via a checkbox in the *I-O Config* dialog. **Only turn on gain tracking *after* calibration.** > **When using the *Smaart IO*, Gain Tracking is active by default. Because of this, the Gain Tracking checkbox is not present.** SPL calibration for Smaart I-O, the Audient EVO series, and the Octa-Capture follows [the same process as any other device being used with Smaart](https://portal.document360.io/v1/docs/amplitude-calibration). To quickly determine the maximum gain adjustment error for your specific device, set input to a gain of 25 dB, then calibrate for sound level measurements using a sound level calibrator with Gain Tracking turned off. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(345).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A06Z&se=2026-11-18T18%3A30%3A06Z&sr=b&sp=r&sig=iQ%2FeYe48Zsc8R5Doxif8v%2FvoQtCM2Qhi33rAWY2eHwU%3D) *To enable Gain Tracking, this checkbox must be selected under I-O Config.* **After** calibrating, with the calibrator still fitted to the microphone and turned on, enable Gain Tracking and assign the input to an SPL meter in Smaart, then observe the measured level as you turn the gain up to 50, and down to 0 dB. The maximum deviation observed from the reference level of the calibrator represents the maximum expected accuracy of your setup. ## EVO Internal Loopback Each of the EVO interfaces include an internal loop channel. This can be used to reference Smaart’s signal generator directly, without the need for an external patch cable. To configure the internal loop-back, select *Use* for one of the loop-back channels in the EVO input device settings. Then, in the Output tab of the *I-O Config* dialog, assign that same channel to be used as an output. The EVO will handle the rest, automatically sending the signal from the selected loop-back output to its corresponding loopback input. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(324).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A06Z&se=2026-11-18T18%3A30%3A06Z&sr=b&sp=r&sig=uGwdZuPBERCBdLEXBhFn1Wfm%2FnNZHCP9f9wT3FtB1kQ%3D) *Then, make sure that same Loopback channel is selected under the Output tab to have the signal generator sent to it.* - EVO 4 loopback channels are inputs 3 & 4 - EVO 8 loopback channels are inputs 5 & 6 - EVO 16 loopback channels are ADAT inputs 15 & 16 A decrease in the level of a signal. Attenuation can refer to reduction in level for a specified frequency range or a decrease in the overall level.