--- title: "All Bands Table" slug: "all-bands-table" updated: 2026-09-30T14:38:41Z published: 2026-09-30T14:38:41Z canonical: "doc360.rationalacoustics.com/all-bands-table" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # All Bands Table The *All Bands* table in Smaart collects [reverberation times](/v1/docs/reverberation-time) and early-to-late energy ratios for all octave and 1/3-octave bands in a single table. Speech intelligibility metrics ([STI, STIPA, and %ALCons](/v1/docs/sti-stipa)) are displayed here as well. The [*Histogram*](/v1/docs/histogram-display) chart can plot any column of the *All Bands* table as a bar graph or line chart in octave or 1/3-octave resolution. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-05-26 at 3.56.16 PM.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A09Z&se=2026-11-18T18%3A42%3A09Z&sr=b&sp=r&sig=9bE5T6cMw8t6Ojcn5DfMAp8AzKY7QGI9XsNpMO%2BlQoQ%3D) *Enabling the All Bands table via the Control Bar button.* ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(287).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A09Z&se=2026-11-18T18%3A42%3A09Z&sr=b&sp=r&sig=OnK5%2FYOxcok3kfJimYunweN0qvXDzkpRM4yN6kOW%2B7U%3D) *The All Bands Table.* Clicking the *All Bands* button at the bottom of the IR mode [Control Bar](/v1/docs/ir-mode-control-bar) brings up a report window. This window contains just about every acoustical quantity that Smaart can automatically calculate from an IR, for each octave and 1/3-octave band, where applicable. Bass Ratio, T Mid, and T Low are calculated automatically from reverberation times for the 125 Hz to 4 kHz octave bands. You may notice in these screenshots that some values are marked in red. This happens when Smaart detects there isn’t enough integration time in the measurement at those bands to calculate a T value. This generally happens when the Impulse Response is not sufficiently above the noise floor and can be improved by using more averaging in the measurement, longer FFT sizes, turning up the stimulus, manually adjusting the Ln positioning, or often a combination of each. Smaart calculates [Ln and the other RT60 integration values](/v1/docs/rt60-level-markers) automatically, but it requires a good measurement to get good data. Older versions of Smaart also include the %ALCons metric, a precursor to STI and STIPA. This metric, however, was never standardized and, due to its controversial nature, it is absent from Smaart versions v9.7 and newer. When multiple IR measurements are displayed, the *All Bands* table analyzes the top trace and will recalculate if the z-axis order of the main graph is changed while the *All Bands* window is open. Smaart can calculate STI from Impulse Response measurements provided that the Time Window is at least 1.6 seconds (though 5+ seconds is preferable), given some additional information about the measurement. If that information has been previously provided and stored in the header of an IR wave file being analyzed, the STI, STIPA, and CIS fields in the *All Bands* Table populate automatically. Otherwise, you can click the Calculate STI button to fill in the necessary details (see [Calculating STI](/v1/docs/calculating-sti) for details). Clicking the *Copy* button in the *All Bands* window copies the entire table to the operating system’s clipboard in tab-delimited ASCII format suitable for pasting into a spreadsheet or any other program that accepts ASCII text. You can also save the information in this window to a text file by clicking the *Export* button. (STI for public address systems) is a less rigorous variant of STI (see above) intended specifically for use in measuring public address systems. STIPA has been validated only for male speech. The only functional difference in how STI and STIPA are measured is that instead of evaluating 13 modulation frequencies in each octave band, STIPA uses only two frequencies per band to cut down the time required for direct measurement of the modulation transfer functions (MTF). Since Smaart calculates the MTF of a system indirectly from its impulse response and all 13 modulation frequencies required for STI are also used for STIPA (just not in every band) there is no particular advantage to using STIPA in Smaart The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function. The amount of time required for and/or represented by a measurement or other process. Often used interchangeably with Time Constant.