--- title: "Advanced Preferences" slug: "advanced-preferences-1" updated: 2026-09-03T19:25:22Z published: 2026-09-03T19:25:22Z canonical: "doc360.rationalacoustics.com/advanced-preferences-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Advanced Preferences The *Advanced* tab of the *Preferences* dialog contains settings for settings that most users will seldom need and may prefer to keep turned off and tucked away when not in use. This menu is only present in Smaart RT, LE, and Suite, but its appearance varies depending on edition. > **Note: LE’s *Advanced Preferences* menu only contains the *Multi-Device* TF checkbox. Being the “Limited feature Edition” of Smaart, other advanced options are not present. Any other features discussed here are present in both RT and Suite, unless otherwise noted.** ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(99).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A11Z&se=2026-11-18T18%3A42%3A11Z&sr=b&sp=r&sig=tGB4NoeS0ZUGP0xsjrVXkgxoV7DB%2BOT45WNVPK8iN8Y%3D) *Smaart Suite’s Options > Preferences > Advanced dialog.* ## Tab & Window Settings - **(Smaart Suite Only):** *Operation Modes (RT, IR, SPL) Open in New Window* – When this option is selected, clicking any of the three operating mode buttons on the Control Bar (or invoking their associated menu commands or keyboard shortcuts) in Smaart Suite opens a new window in the selected operating mode instead of switching the current tab to that mode. - *Stop Measurements on Tab Change* – When this option is checked, Smaart automatically stops all running measurements on a tab when you switch to another tab in the same window. When unchecked, live measurements running on all tabs continue running until you stop them yourself or exit the program. The advantages of allowing background operation are that when you come back to a tab, you don’t have to restart all of your measurements again and wait for their averages to populate. Also, if a remote client is subscribed to the window, then changing tabs on the host machine does not interrupt measurement data being streamed to the client. The caveat is that if you have a lot of measurements running on multiple tabs, a lot of processor cycles can get eaten up crunching data that you are not actually using and performance may suffer as a result. ## Transfer Function Settings - *Allow Multi-Device Transfer Function* lets you select input channels from two different input devices as your reference and measurement Signal sources for transfer function measurements. Please be aware that this will really only work if the sample clocks for the two devices are synchronized somehow, and even then you may encounter issues with relative delay time between the two devices changing when you stop and restart a measurement. - *Frequency-*Domain *Time Windowing (*FTW*)* is a complex linear smoothing technique performed in the frequency domain that is mathematically equivalent to applying a tapered window function to the Impulse Response in the time domain and transforming the result with a zero-padded FFT. FTW is applied globally to all live and captured transfer function measurements that use Complex Magnitude averaging (only). Note turning on this feature forces the global magnitude averaging selection *(Mag Avg Type)* for live transfer function measurements (see above) to Complex. When FTW is enabled, controls for turning it on and setting the nominal Time Window appear on the Control Bar in the main window. Please see the [*Frequency Domain Time Windowing*](/v1/docs/frequency-domain-time-windowing) for more information. - [*Sync-Source™ TF* (synchronous source transfer function)](/v1/docs/synchronous-source-syncsource-measurements) is real-time transfer function measurement technique that uses a periodic excitation signal (pseudorandom Pink Noise or pink sweep) with a cycle length equivalent to that of the FFT size. When Sync-Source is enabled, controls are added to the transfer function Control Bar in the main window for specifying the Stimulus signal and FFT Length. - [*L-IFFT™*](/v1/docs/l-ifft-live-inverse-fast-fourier-transform), or Live Inverse Fourier Transform, is an alternate view of the Live IR plot that uses the single time record FFT calculated with every transfer function measurement in Smaart to plot an absolute time referenced live impulse response with the benefits of a real time transfer function measurement applied to it - specifically averaging and magnitude thresholding. When L-IFFT is enabled, a secondary drop down in the Live IR graph allows you to select between Live IR and L-IFFT. - [*Enable Plot Time Reference (PTR)*](/v1/docs/ptr-plot-time-reference) enables a new control in the lower left of any Phase plot(s). This control is disabled when a live measurement is the top of the Z order. Please visit the [*Graph Legends*](/v1/docs/graph-legends) chapter for more information on PTR. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays. Frequency-domain “time windowing” (FTW) is a complex linear smoothing technique performed in the frequency domain that is mathematically equivalent to applying a tapered window function to the Impulse Response in the time domain and transforming the result with a zero-padded FFT. In practice, FTW applies smoothing in the time domain, and can be a useful companion to frequency domain smoothing, especially when used with longer time values (50ms+). The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. The amount of time required for and/or represented by a measurement or other process. Often used interchangeably with Time Constant. A random (or pseudorandom) signal in which, over a given averaging period, each Octaveband (or other logarithmically spaced interval) contains an equal amount of energy. Phase, or Phase shift is a timing difference in a signal (relative to some reference) at one or more frequencies, typically expressed in degrees, where 360° = one full cycle at a given frequency.